Building code · For homeowners

Window fall protection in Alberta: sill heights and limiters

In Alberta, an openable window needs a guard or a 100 mm limiter unless its sill is over 900 mm up or the drop outside is under 1 800 mm, as of 2026.

Owner, 1to1 Plans Calgary

Updated · 9 min read

In Alberta, an openable window in a home needs a guard or a limiter that holds the opening to 100 mm (3.9 in), unless the bottom of the part that opens is more than 900 mm (2 ft 11 in) above the floor, or less than 1 800 mm (5 ft 11 in) above the ground outside (NBC(AE) 2023, 9.8.8.1). The rule exists to stop small children falling from open windows. It's in the second printing of the National Building Code, 2023 Alberta Edition, in force since 17 August 2026 (Government of Alberta, 2026).

Key takeaways

  • As of October 2026, openable windows in Alberta homes need a guard, or a limiter that only tools or special knowledge can release, holding the opening to 100 mm (3.9 in) (NBC(AE) 2023, 9.8.8.1.(4)).
  • No protection is needed where the bottom of the opening part is more than 900 mm (2 ft 11 in) above the floor, or less than 1 800 mm (5 ft 11 in) above the ground on the other side (NBC(AE) 2023, 9.8.8.1.(5)).
  • The code's note says rotary crank operators can't limit a window to 100 mm, even with the handle removed (NBC(AE) 2023, Note A-9.8.8.1.(4)).
  • A door in a home with a drop of more than 600 mm (2 ft) on the other side, like a Juliet balcony, needs a guard or a stop holding it to 100 mm (NBC(AE) 2023, 9.8.8.1.(3)).
  • Inside a home, glazing over a stair or landing that comes lower than 900 mm (2 ft 11 in) above the treads needs a guard, or must be fixed shut and built to take balcony guard loads (NBC(AE) 2023, 9.8.8.1.(7)).
  • Door glass over 0.5 m² (5.4 sq ft) that reaches within 900 mm of the bottom of a home's entrance door must be safety glass (NBC(AE) 2023, 9.6.1.4).

When does a window need fall protection in Alberta?

Any openable window in a residential building needs it, unless one of two exemptions applies. The rule isn't limited to bedrooms or to upper floors. The exemptions do most of the sorting (NBC(AE) 2023, 9.8.8.1.(4) and (5)):

  • A high sill. The bottom edge of the openable part sits more than 900 mm (2 ft 11 in) above the finished floor.
  • A short drop. That same edge sits less than 1 800 mm (5 ft 11 in) above the floor or ground on the other side.

The code's note explains the target. It is meant for small children, and in practice it reaches windows on the second floor or higher (NBC(AE) 2023, Note A-9.8.8.1.(4)). Notes are guidance; the Sentence is the rule. The note also links the two numbers: the 900 mm sill matches the 900 mm guard height inside a home.

Here's how the exemptions sort typical windows in a house, as of October 2026:

WindowBottom of the opening, from the ground outsideBottom of the opening, from the floorProtection needed?
Main floor, over a garden bedLess than 1 800 mm (5 ft 11 in)Any heightNo
Upper floor, over a deck whose floor is less than 1 800 mm belowLess than 1 800 mm, measured to the deckAny heightNo
Upper floor, high sill1 800 mm or moreMore than 900 mm (2 ft 11 in)No
Upper floor, low sill or floor-length window1 800 mm or more900 mm or lessYes: a guard or a 100 mm (3.9 in) limiter
Main floor, on the walkout side of a house1 800 mm or more900 mm or lessYes

Note: measured to the bottom of the part that opens, not the frame. The City of Calgary decides how the rule applies to a particular window at plan review.

A fixed pane isn't covered by the window rule, since it doesn't open. Large fixed glass beside a stair is covered by a different rule, explained further down.

What counts as a window opening limiter?

A device that holds the window to an opening of 100 mm (3.9 in) or less, measured either way, and that can only be released with tools or special knowledge (NBC(AE) 2023, 9.8.8.1.(4)). The note calls 100 mm the largest opening that protects small children.

The note is specific about hardware. It lists a fixed-stop lever, a fixed-length cable and a fixed-position stop block as devices that can work. Rotary operators, the cranks used on casement and awning windows, can't do it, "even when the crank handle is removed" (NBC(AE) 2023, Note A-9.8.8.1.(4)). It warns that awning windows with scissor hardware may swing open once unlatched, that hopper windows matter only if they open at the bottom as well, and that sliders are the type the rule affects most. For technical detail, it points to ASTM F2090 on window opening control devices.

This drawing compares the same 920 mm tall opening held to the 100 mm limit and opened to the 380 mm width an escape window needs:

One window, limited and fully openHeld to 100 mm: 100 mm by 920 mm, 0.09 square metres; Escape opening: 380 mm by 920 mm, 0.35 square metres100 mm920 mm0.09 m²Held to 100 mm380 mm920 mm0.35 m²Escape opening
One window, limited and fully open A 920 mm tall opening held to 100 mm, beside the same height at 380 mm wide, the code note's example of a 0.35 m² escape opening. Drawn to scale.

The 380 mm by 920 mm opening is the code's own example of the smallest tall escape window, at 0.35 m² (3.8 sq ft) (NBC(AE) 2023, Note A-9.9.10.1.(2)). Held to 100 mm, the same window opens to about 0.09 m².

What if the window is also the bedroom's escape window?

Then the two rules pull against each other, and a high sill is the simplest way out. Every bedroom without sprinklers needs a window or outside door that opens "without the use of keys, tools or special knowledge" to at least 0.35 m², with no side under 380 mm (NBC(AE) 2023, 9.9.10.1). A limiter, by definition, needs tools or special knowledge to release. The code text doesn't say how to reconcile the two on one window.

Calgary's egress advisory reads special knowledge as anything more than one simple motion to release the lock and one simple motion to open the window (The City of Calgary, egress advisory 2022). If you want a limiter on a bedroom's escape window, ask the City before you order the windows.

Raising the sill avoids the conflict. Above 900 mm (2 ft 11 in), the fall rule no longer applies, and the code's note on escape windows suggests sills no higher than 1.5 m (1 500 mm, or 4 ft 11 in) so people can reach them (NBC(AE) 2023, Note A-9.9.10.1.(1)). That's guidance; the code sets no maximum sill height.

Here's how the sill height plays out on an upper-floor bedroom window with a drop of 1 800 mm or more outside, as of October 2026:

Sill (bottom of the opening part) above the floorFall protectionEscape window
900 mm (2 ft 11 in) or lowerGuard or 100 mm limiter requiredA limiter needing tools or special knowledge conflicts with the escape rule; ask the City
More than 900 mm, up to 1.5 m (4 ft 11 in)Not requiredWithin the note's suggested range
More than 1.5 mNot requiredAbove the note's suggestion; the note recommends built-in furniture below to help

Note: the 1.5 m figure is guidance from Note A-9.9.10.1.(1), not a requirement. Window sizes for escape are on the egress window guide.

The drawing shows those two heights on a bedroom wall, with a ceiling at 2 100 mm (6 ft 11 in), the minimum height the code sets over part of every bedroom (NBC(AE) 2023, Table 9.5.3.1).

Sill heights on an upper-floor bedroom wallCeiling 2 100 mm (6 ft 11 in); sill above this needs no limiter 900 mm; suggested top of an escape sill 1 500 mm.2 100 mm ceiling900 mm: sill above this needs no limiter1 500 mm: suggested top of an escape sill
Sill heights on an upper-floor bedroom wall Above 900 mm, no fall protection is needed; the code's note suggests escape sills no higher than 1 500 mm. Drawn to scale.

Does a Juliet balcony need a guard in Alberta?

Yes: a door in a home that opens onto a drop of more than 600 mm (2 ft) needs a guard, or a mechanism that limits the door to an opening of 100 mm (3.9 in) (NBC(AE) 2023, 9.8.8.1.(3)). That covers a French door on an upper floor with no balcony behind it, and a patio door left waiting for a deck that hasn't been built.

The 600 mm trigger is the same one that applies to floors and decks. The guard height guide covers guard heights, baluster spacing and loads.

What about glass beside stairs and doors?

Glass near a stair has its own rule. Inside a home, glazing over stairs, ramps and landings that comes lower than 900 mm (2 ft 11 in) above the treads or landing needs a guard, or must be fixed shut and designed for the lateral loads on balcony guards. Outside homes, the trigger is 1 070 mm (3 ft 6 in) (NBC(AE) 2023, 9.8.8.1.(6) and (7)). In residential buildings, glass in public areas above the second storey that comes within 1 m (3 ft 3 in) of the floor gets the same treatment.

So a big window on a stair landing should start at least 900 mm above the landing, or be planned as a fixed, guard-rated panel. The stair guide shows the landing sizes.

Glass in and beside doors must be safety glass in a few cases. That covers glass in sliding and storm doors, and sidelights over 500 mm (1 ft 8 in) wide that could be mistaken for doors, within or at the entrance to a home. It also covers glass in entrance doors over 0.5 m² (5.4 sq ft) that reaches within 900 mm of the bottom of the door (NBC(AE) 2023, 9.6.1.4). Safety glass here means tempered or laminated glass, or wired glass. How much window a side wall can have near the property line is a separate rule, covered in the windows near the property line guide.

What does a walkthrough show about windows?

Windows show on the LED floor where they sit in each wall, and the elevations go up on the wall-size screen behind the floor, so you see the sill heights beside the room they serve. Standing in a bedroom at full size, you can check where the bed and a desk sit against a window, and whether a landing window lines up with the stair. Changes are made on the spot.

You keep the recording of every session. Sessions are quoted for your plan, with nothing to pay at booking (how quotes work). See the other building code guides and the bedroom size guide, or book a session.

Questions

What is the minimum window sill height in Alberta?

Alberta's building code sets no minimum sill height, as of October 2026. An openable window whose sill is 900 mm (2 ft 11 in) or lower, with a drop of 1 800 mm (5 ft 11 in) or more outside, needs a guard or a limiter holding the opening to 100 mm (3.9 in).

Are window opening limiters required in Alberta?

Window opening limiters are one of two ways to meet Alberta's window fall rule; a guard is the other. You need one or the other on an openable window unless its sill is more than 900 mm above the floor or the drop outside is less than 1 800 mm.

Can a crank window be limited to 100 mm?

No: the code's note says rotary crank operators can't limit an opening to 100 mm, even with the handle removed, so a crank window can't act as its own guard. A fixed stop, cable or stop block is the kind of device the note describes.

Does a Juliet balcony need a railing in Alberta?

Yes: in Alberta, a door in a home with a drop of more than 600 mm (2 ft) on the far side needs a guard, or a stop that limits the opening to 100 mm (3.9 in). A Juliet balcony's railing is that guard.

Can a bedroom egress window have a limiter in Alberta?

A bedroom escape window in Alberta must open without keys, tools or special knowledge, while a fall limiter must need tools or special knowledge to release. The code doesn't say how to square the two, so the simplest plan is a sill above 900 mm (2 ft 11 in); otherwise, ask the City of Calgary before you choose hardware.

Sources

  1. NBC(AE) 2023, 9.8.8.1 nrc-publications.canada.ca
  2. Government of Alberta, 2026 alberta.ca
  3. The City of Calgary, egress advisory 2022 calgary.ca
Said Halat

Written by

Said Halat

Said runs 1to1 Plans Calgary, the studio at Unit 105, 2750 22 St NE where people walk their floor plans at full size. He's a licensed electrician and has worked in construction since 2011.

About Said and the studio
The complete studio with real furniture and a full-scale house elevation

Unit 105 · 2750 22 St NE

Come walk your plans

Every day, 9 am to 5 pm, by appointment. In the South Airways business park in northeast Calgary, with parking at the door.

Email
calgary@1to1plans.com